Batteryless cardiac pacemaker design based on automatic wristwatch

Photo 1: The energy-harvesting device is sutured directly onto the myocardium.

 

 

A new cardiac pacemaker based on an automatic wristwatch and powered by heart motion was presented at the ESC Congress 2014 in September by Adrian Zurbuchen from Switzerland. The prototype device does not require battery replacement.

Zurbuchen presented a way to power a cardiac pacemaker with an alternative energy source: the heart motion.

"Batteries are a limiting factor in today's medical implants," said Zurbuchen, a PhD candidate in the Cardiovascular Engineering Group at ARTORG, University of Bern, Switzerland. "Once they reach a critically low energy level, physicians see themselves forced to replace a correctly functioning medical device with a surgical intervention. This is an unpleasant scenario that increases costs and the risk of complications for patients."

Four years ago, Professor Rolf Vogel, a cardiologist and engineer at the University of Bern, had the idea of using an automatic wristwatch mechanism to harvest the energy of heart motion. "The heart seems to be a very promising energy source, because its contractions are repetitive and present for 24 hours a day, 7 days a week," Zurbuchen said. "Furthermore the automatic clockwork, invented in the year 1777, has a good reputation as a reliable technology to scavenge energy from motion."

The researchers' first prototype is based on a commercially available automatic wristwatch. All unnecessary parts were removed to reduce weight and size. In addition, they developed a custom-made housing with eyelets that allows suturing the device directly onto the myocardium (photo 1).

The prototype works the same way it would on a person's wrist. When it is exposed to an external acceleration, the eccentric mass of the clockwork starts rotating. This rotation progressively winds a mechanical spring. After the spring is fully charged, it unwinds and thereby spins an electrical micro-generator.

Photo 2: The batteryless pacemaker was tested by connecting the energy-harvesting device to an electronic circuit that transformed and stored the signal into a small buffer capacity. The buffered energy was used to power a custom-made cardiac pacemaker. Electrical stimuli were delivered to the heart by epicardial leads.

 

 

 

 

To test the prototype, the researchers developed an electronic circuit to transform and store the signal into a small buffer capacity. They then connected the system to a custom-made cardiac pacemaker (photo 2). The system worked in three steps. First, the harvesting prototype acquired energy from the heart. Second, the energy was temporarily stored in the buffer capacity. And finally, the buffered energy was used by the pacemaker to apply minute stimuli to the heart.

The researchers successfully tested the system in in-vivo experiments with domestic pigs. The newly developed system allowed them, for the first time, to perform batteryless overdrive pacing at 130 beats per minute.

"We have shown that it is possible to pace the heart using the power of its own motion," said Zurbuchen. "The next step in our prototype is to integrate both the electronic circuit for energy storage and the custom-made pacemaker directly into the harvesting device. This will eliminate the need for leads.

"Our new pacemaker tackles the two major disadvantages of today's pacemakers," said Zurbuchen. "First, pacemaker leads are prone to fracture and can pose an imminent threat to the patient. And second, the lifetime of a pacemaker battery is limited. Our energy-harvesting system is located directly on the heart and has the potential to avoid both disadvantages by providing the world with a batteryless and leadless pacemaker."

Source: European Society of Cardiology

Published December 2014

Rate this article

[Batteryless cardiac pacemaker design based on automatic wristwatch]

Very interesting, with information I can use
Interesting, with information I may use
Interesting, but not applicable to my operation
Not interesting or inaccurate

E-mail Address (required):

Comments:


Type the number:



Copyright © 2014 by Nelson Publishing, Inc. All rights reserved. Reproduction Prohibited.
View our terms of use and privacy policy